Calibrated Goldilux Light Meters

Supplied with an accredited calibration certificate either SANAS or ANAB. (ISO17025 Laboratory)

Goldilux Laboratory Calibrated Lightmeter Range

 Goldilux Lightmeter’s allow external probes to be attached, expanding their light measurement range.

Autoranging Light Meter

Spectral Range:
0-20 000 LUX, resolution of 0.1 LUX.

This Digital and Auto-ranging Light meter is the most stable, robust and reliable light measuring instrument suitable for indoor light measurement.

APPLICATIONS:

  1. Occupational health and safety light measurements.
  2. Mining vehicle light tests at a distance.
  3. Safety in mining.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Autoranging Light Meter for LED’s

Spectral Range:
0-20 000 LUX, Bestseller, Certificate of conformance only (Can be combined with a GALP-1L)

The Goldilux LEDLUX is an illuminance meter specifically calibrated for high accuracy measurement of LED lighting. Guaranteed performance for white LEDs with colour temperature from 2700k to 6500k. The instrument is issued with a Certificate of Conformance. An accredited certificate endoresed by an ISO 17025 lab is available as an option. All the usual features of quality of the Goldilux light meter asl apply to the LEDLUX.

APPLICATIONS:

  1. Occupational health and safety light measurements without legal standing.
  2. Safety in mining without legal standing (Usually used by low ranking miners).
  3. Personal use light meter.
  4. Robust instrument for tough physical environments.

Autoranging Light Meter

Spectral Range:
0-200 000 LUX, For measurement of outdoor and powerful lighting.

This Digital and Auto-ranging Light meter is the most stable, robust and reliable light measuring instrument suitable for outdoor and powerful light measurement.

APPLICATIONS:

  1. Occupational health and safety light measurements.
  2. Mining vehicle light tests at a distance.
  3. Safety in mining.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Autoranging Light Probe

Spectral Range:
0-200 000 LUX, Can be plugged into Goldilux meter or readout unit.

This Digital and Auto-ranging Light meter is the most stable, robust and reliable light measuring instrument suitable for outdoor and powerful light measurement.

APPLICATIONS:

  1. Occupational health and safety light measurements.
  2. Mining vehicle light tests at a distance.
  3. Safety in mining.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Readout unit for light/UV probe

Spectral Range:
Depends on probe.

Combining a probe for visible light and UV-A meter – or vice versa (using a visible light meter with a UV-A probe)- will result in a most effective measurement system for visible and the UV-A spectral range. A UV-A meter can also be paired with a UV-B probe and a UV-C probe. Alternatively a Display (no sensor) can be used with alternative connection of UV-A, UV-B or UV-C probes.

Must be used in conjuction with a probe or readout is redundant.

APPLICATIONS:

  1. Occupational health and safety light measurements.
  2. Mining vehicle light tests at a distance.
  3. Safety in mining.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Phototherapy Analyser

Spectral Range:
400 – 500 nm

The phototherapy radiometers have been designed to measure the effective irradiance of blue light used for the treatment of jaundice in new-born babies (hyperbilirubinaemia).

Can be used in conjuction with a skin contact Bilirubin meter.

APPLICATIONS:

  1. Occupational health and hygiene measurements.
  2. Verify output of Bilirubin lamps (Traditional or LED).
  3. Additional instrument for skin Bilirubin meter for hospitals.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Goldilux UV-A Meter

Spectral Range:
330-400 nm, microW/cm^2, 0 to 200 000 microW/cm^2

UV-A light sources may also find use in causing fluorescence on bank notes to check if they are legit or may be applied for curing of glues and resins in certain manufacturing industries.

APPLICATIONS:

  1. Occupational health and hygiene measurements.
  2. Verify output of NDT and curing lamps.  (Traditional or LED).
  3. Can be used in orchards or indoor growth applications.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Goldilux UV-A probe (sensor only)

Spectral Range:
330-400 nm, microW/cm^2, 0 to 200 000 microW/cm^2

UV-A light sources may also find use in causing fluorescence on bank notes to check if they are legit or may be applied for curing of glues and resins in certain manufacturing industries.

APPLICATIONS:

  1. Occupational health and hygiene measurements.
  2. Verify output of NDT and curing lamps.  (Traditional or LED).
  3. Can be used in orchards or indoor growth applications.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Goldilux UV-B probe (sensor only)

Spectral Range:
Ionizing radiation in the range of 250-320 nm, microW/cm^2, 0 to 200 000 microW/cm^2

UV-B radiation is used for therapeutic exposure under medical supervision (e.g. Psoriasis and similar skin conditions).

APPLICATIONS:

  1. Occupational health and hygiene measurements.
  2. Verify output of suntanning booths or Psoriasis light treatment lamps.  (Traditional or LED).
  3. Legal standing in any measurements.
  4. Robust instrument for tough physical environments.

Goldilux UV - C Light Probe (Sensor only)

Spectral Range:
Short wave ionizing radiation, 225-280 nm, microW/cm^2, 0 to 200 000 microW/cm^2

UV-C sources must be out of line of sight. Measurements are best with a meter system (consisting of the probe and a display) to check that the lamps are emitting the short-wave radiation at a wavelength of 253.7 nm standing at a distance. The probe – display system allows measurement at a distance of 3 m as a standard.

APPLICATIONS:

  1. Occupational health and hygiene measurements.
  2. Verify output of hospital germicidal UV lamps.  (Traditional or LED).
  3. Can be used to verify welding UV emissions.
  4. Legal standing in any measurements.
  5. Robust instrument for tough physical environments.

Additional Goldilux Information

The GOLDILUX SERIES of PROFESSIONAL LIGHT METERS are designed to measure ILLUMINANCE of VISIBLE SPECTRAL RADIATION in LUX units.

A South African Product – developed at the CSIR and manufactured by MIT, the instrument range offers value for money, reliability and a better a higher recalibration accuracy than the BROADER INDUSTRY STANDARD.

Generally, they are a very sturdy and robust instruments in a housing suitable to withstand tough environments. Yet, the measurement operation is easy and straight-forward featuring a reading HOLD switch on top. Goldilux remains very precise over time and has excellent re-calibration accuracy, within 3% or less.

An external probe, of any GOLDILUX type, may be plugged into or attached to a LIGHT METER OR GAL-3L readout, in this case the detector in the light meter is automatically disconnected – and the displayed reading corresponds to the QUANTITY and UNITS measured with the PROBE.

The LCD (display) of the meters (GAL-2L, GAL-2H) is auto-ranging, self-adjusting, over one decimal (dot placement). External probes (e.g. GALP-1L) have a built-in probe gain selector switch (under the access flap) with two different settings – the probes therefore cover a wider range of readings with one fixed detector, full resolution is obtained by leaving the instrument in the lower settings, allowing for more precise readings with low light or irradiation output by a source.

Power source is a 9V battery. For long lifetime and best performance use an ALKALINE battery.

When not in use, always put the protective cap on the detector and keep the instrument in a safe place.

The ‘LOW BATTERY’ warning will come up on the screen when the battery needs replacing.

If necessary, clean the detector with a soft cloth and alcohol. Dry and polish if desired, there should be no grime or smudges on the white diffuser (as this may affect readings).

Corrosion of the doped glass of the detector may take place during high-intensity use in excessively salty climates. If you suspect this situation, have your meter recalibrated or ask the manufacturer for an inspection.

Generally, the Goldilux meters are a very sturdy and robust range of instruments (suitable for heavy duty mining environments). They are easy and straight-forward to operate.

Goldilux remains very precise over time and has excellent re-calibration accuracy, within 3% or less. 

Our light meters have a good established reputation as a value brand, that offers quality, accuracy and reliability again and again. Certain meters can drift by up to  30% over 6 months.  Goldilux usually have a high recalibration accuracy of 3% or less and a reading the generally remains precise over time – i.e. even over a period of 3 years.

This applies to meters used underground in mining for health and occupational safety light measurement, occupational hygiene industries for measuring UVGI irradiation, health industries including hospitals and lighting design (luminaire) design. Sports (e.g. cricket umpiring) can also benefit from accurate light level measurement, to have fair play.

Orchards and rare plant growers may improve yields by measuring specific wavelengths (e.g. UV-A) that may be responsible for better plant growth and therefore more efficient absorption of respective ground nutrients and hormone supplements.

The trade name represents a standard of quality. Each instrument is sold with an accredited laboratory calibration certificate, this is standard and included in the purchase price.

An Intrinsic Safety (IS) test certificate is also available for certain models. 

Each instrument is guaranteed for one (1) year for defects in workmanship. Instruments are sold to a formalized distributor network mainly, however, some exceptions are made to customers who are keen to order an instrument directly from us at retail prices. We always welcome new distributors. Once your required documentation is in place and you are registered as a distributor with us, you are able to purchase instruments from us at distributor prices, this is a special privilege.

An external probe, of any GOLDILUX type, may be plugged into or attached to a UV METER OR GAL-3L readout, in this case the detector in the UV meter is automatically disconnected – and the displayed reading corresponds to the QUANTITY and UNITS measured with the

PROBE. The LCD (display) of the meters (GUVA-1L) is auto-ranging, self-adjusting, over onedecimal (dot placement).

Light is measured in lux and UV light in microwatts per square cm. The UV meters and probes have been specifically designed and calibrated for use with narrow-band UV sources (most UV lamps). In such UV sources most of the UV radiation is emitted in a narrow wavelength region around a dominant spectral line. For, example, in case of Phillips UV-B lamps, there is a focus on narrow-band UV-B for the treatment of psoriasis and in new UVGI (germicidal UV) lamps for health and occupational hygiene, these also peak at 253.7nm of the UV-C spectrum, therefore these also refer to narrow band UV sources. Sometimes, a probe and a GAL-3L readout are casually referred to as ‘a meter’. The cable enables the user to shield himself from dangerous radiation behind a barrier like a wall, for example.

If the UV-A and UV-B meters have to be used for the measurement of wide-band UV sources (which emit UV radiation over a wide range of wavelenghts, like for instance sunlight), this should only be done after having the meters re-calibrated for that specific type of wide- band source. UV-C meters should not be used for measurements on wide-band sources like sunlight at all, quite apart from the fact that there is no UV-C component in sunlight.

Modern UV-C detectors are also designed to be “solar blind” as a way to discriminate broad spectrum radiation from pure UV-C light sources. The different UV regions are internationally defined as follows: UV-A: 315 – 400 nm, UV-B: 280 – 315 nm, UV-C: 100 – 280 nm.

The Goldilux instruments feature a hold button, which allows the user to obtain a specific reading at an exact physical point of measurement.

The Goldilux brand of instruments has an established network of distributors throughout South Africa for numerous decades. Feel free to order your instrument today from a distributor near you, that caters for your industry or we at MIT can also assist your enquiry. Calibrations normally come in two basic formats, an initial calibration and a full calibration.

An initial calibration (with calibration certificate) is provided upon purchase of your Goldilux instrument. After the instrument has been in service by the end user (until the next calibration is due), it is normally required to undergo a full calibration or 5 point calibration, to ensure the instrument is still working correctly – or in other words putting it through it’s paces. Calibrations normally satisfy a legal obligation, where CORRECT measurements are essential and backed up with an accredited laboratory calibration. When instruments are privately and casually used, when legal requirements are less of a concern, then the sensor remains stable for a very long time, this is especially true at inland areas. Coastal areas, with excessive, daily fog, condensation and very salty climates, require the instrument to be calibrated, definitely, within the requirements of the calibration sticker. Often what happens, is that salt crystals may form on the detector of ANY instrument, therefore affecting correct readings (and distorting light input). On the other hand, acid fumes may also affect the detector coatings of any instrument, therefore, if you operate in such environments and contexts, calibrations become much more important.

Ledlux
GALP-1L

GAL-2L, GAL-2H, GAL-3L with GALP-1L PROBE

GUVA-1L, (GBIL-1L), GUVAP-1L, GUVBP-1L, GUVCP-1L (UV-C & UVGI, UV GERMICIDAL)

Instruments are calibrated by accredited Calibration Labs. 

Full certification is free for new instruments. Re-calibration can be arranged at regular intervals.

Accreditation is by ANAB or SANAS.

LEDLUX  – C of C certificates available from MIT. Additional calibration also available through Calibration Labs with ISO 17025 certification.

Request Calibration Certificates – please contact us by phone or e-mail.

Measurement parameter: Illuminance – visible Light Lux or Kilo Lux

Irradiance (power per unit area)  microW / cm2– Blue Light and UV radiation

Meters and Probes: Readout: 4½ digit LCD  display with autoranging over one decade.

Power source: 9V type PP3 battery. Battery life approximately 200 hours for alkaline battery (without using an external probe).

Detector:  Solid state sensor, UV-enhanced silicon photodiode with filtering for Blue Light, UV-A, UV-B or UV-C.

Spectral response: As indicated in Fig. 4 (nominal values).

Accuracy:  Light meter uncertainty – usually within 1%, UV meters Factory setting 5% (UV-A), 10% (UV-B), 15% UV-C. These figures are applicable for line sources centred at 365 nm (UV-A), 313 nm (UV-B) and 254 nm (UV-C). Otherwise, as stated on the calibration certificate by a recognized calibration laboratory.

Angular response: Good directional response of light meters compared with ideal cosine response. Also with the UV meters very good match with the ideal cosine response.

Dimensions, Meters: 150 x 80 x 37 mm, Probes: 110 x 60 x 30 mm. Mass, Meters:
230 g (with battery)

Probes: 120 g (with cable). Accessories: Protective cap for detector, manual.

Intrinsic Safety (IS) Certification available for the following Models: 

LEDLUX

GAL-2L

GUVAP-1L UV-A Probe (sensor).

We have a minimum guarantee that a meter/instrument will be in working condition for at least one (1) year. This is just our guarantee and our meters keep on working fault free for many decades.

If an approved distributor receives notice of such defects during the warranty period, he will either, at his option, repair or replace products which prove to be defective and receive a replacement from the manufacturer.

Exclusions
The above warranty shall not apply to defects resulting from improper or inadequate maintenance by the customer, customer-supplied software or interfacing, unauthorized modifications or misuse, operation outside the environmental specifications for the product, improper site operation and maintenance, an accident or abuse.